HG-CF-1205 Rev. 0 - 06.01.10 Page 1 B40 & X40 Metallic FDA ‘05’ models This pump is Atex approved for use in potentially explosive atmospheres
HG-CF-1205 Rev. 0 - 06.01.10 Page 10 PARTS LIST REF No. DESCRIPTION QTY ST. STEEL / COMMON SA MODELS 1 40-224 BASE LEG 2 2 D372 SKT
HG-CF-1205 Rev. 0 - 06.01.10 Page 11 Sectional General Assembly :- B4005SA Model Pump, refer to page 10 Parts List table for Item Ref. Nos. Lip Seal P
HG-CF-1205 Rev. 0 - 06.01.10 Page 12 Des Monaghan, Production & Technical Manager HG-CF-223 (REV 5) IDEX Pump Technologies (Ireland) Ltd., A Unit
HG-CF-1205 Rev. 0 - 06.01.10 Page 2 Date Details Completed Service / Maintenance Log Contact Phone / Fax No. Contact Information RECYCLING
HG-CF-1205 Rev. 0 - 06.01.10 Page 3 B40 Metallic Pump Performance curve, performance based on water at ambient temperature GA Drawing & Performanc
HG-CF-1205 Rev. 0 - 06.01.10 Page 4 FLUID CONNECTIONS CAPACITY MAX SOLIDS MAX DISCHARGE HEAD DISPLACEMENT/STROKE DIN 50 Tri-Clamp size Other optio
HG-CF-1205 Rev. 0 - 06.01.10 Page 5 PRINCIPLE OF PUMP OPERATION This ball valve type diaphragm pump is powered by compressed air and is a 1:1 ratio d
HG-CF-1205 Rev. 0 - 06.01.10 Page 6 Before pump operation, inspect all gasketed fasteners for looseness caused by gasket creep. Re-torque loose fasten
HG-CF-1205 Rev. 0 - 06.01.10 Page 7 TROUBLE SHOOTING GUIDE NOTE :- Check all solutions before dismantling the pump. PROBLEM CAUSE SOLUTION Pump will
HG-CF-1205 Rev. 0 - 06.01.10 Page 8 Read these instructions completely, before installation and start-up. It is the responsibility of the purchaser to
HG-CF-1205 Rev. 0 - 06.01.10 Page 9 EXHAUST SAFETY WHEN PUMPING HAZARDOUS LIQUIDS Suction Lift Installation Flooded Suction Installation Submerged Ins
Commentaires sur ces manuels